Chlorine taste and odor point to activated carbon, such as the Viomi Under-Sink Carbon Filter at its own drinking faucet, while dissolved salts point to reverse osmosis (RO), such as the Viomi M1, which also has SGS testing for lead and PFOS/PFOA reduction. Lead and PFAS can be handled by carbon or RO models certified or tested for those specific contaminants, while nitrate, fluoride, and pentavalent arsenic call for RO systems listed for them. Germs need treatment validated for the organisms involved. Your utility's annual water quality report lists what was detected in the public supply, and a lab test measures what is in your own tap or private-well sample.
Your Water Report Shows What to Treat
If you're on city water, your utility publishes an annual Consumer Confidence Report. The EPA's Consumer Confidence Report page points readers to it to learn more about the quality of drinking water in their area. It lists each regulated contaminant the utility detected, the level found, and the legal limit.
A utility report does not cover the following:
- What happens inside your home's pipes. Lead usually enters water from service lines, solder, and fixtures, and the EPA notes that testing is how you find out whether it is in the water from your own tap (EPA lead basics).
- Private well water. Wells fall outside utility reports, so a certified lab test is the starting point.
The CDC links the two steps directly: testing your water is what helps you choose a filter.
When you read a report or lab result, look at three columns: the contaminant, the measured level, and the limit (an MCL, or for lead and copper, an action level). Any contaminant you want to reduce, plus anything that bothers you about taste or smell, goes on your shopping list.
Each Technology Targets Different Problems
Each technology is built for certain problems. Certification standards set out how each claim is tested.
| Technology | Common formats | Certification standards for its claims | Strongest at | Plan a separate step for |
|---|---|---|---|---|
| Activated carbon (granular or carbon block) | Pitchers, faucet mounts, under-sink cartridges | NSF/ANSI 42 (taste and odor), 53 (health effects), 401 (emerging contaminants) | Chlorine, chloramine, taste and odor; lead, PFAS, VOCs, and microplastics when the model's evidence names them | Dissolved salts, nitrate, and germs |
| Ion exchange | Many pitcher cartridges, softeners | NSF/ANSI 42, 53 (pitchers); NSF/ANSI 44 (softeners) | Metals such as copper and mercury in pitchers; hardness in softeners | Organic chemicals and germs |
| Reverse osmosis | Under-sink and countertop systems | NSF/ANSI 58, often with 42 and 53 for its carbon stages | Dissolved solids, plus nitrate/nitrite, fluoride, pentavalent arsenic, lead, and PFAS when the model's evidence names them | Microbial concerns beyond the system's organism-specific claims and source-water conditions |
| UV or microbiological purifier | UV units, specific RO add-ons | NSF/ANSI 55 Class A (UV disinfection), NSF Protocol P231 (microbiological purifiers) | Bacteria, viruses, cysts, within each listing's conditions | Chemicals |
| Whole-house filters and softeners | Point of entry, at the main line | NSF/ANSI 42, 44, 53 for specific claims | Chlorine and hardness at every tap | Drinking-water contaminants that need point-of-use treatment |
EPA guidance on secondary standards names reverse osmosis, distillation, and electrodialysis as effective at removing chloride, total dissolved solids, and other inorganic substances (EPA secondary standards). Chloramine calls for carbon: a WQA technical bulletin ranks activated carbon as "the most effective nonchemical method" for removing it (WQA chloramine bulletin).
Model-Level Evidence by Contaminant Group
The tables below pair each contaminant group with model-level certification listings, and each row names the standard and the certifier.
Chlorine, chloramine, taste, and odor
| Model | Technology | Evidence |
|---|---|---|
| Brita Standard filter OB03 | Carbon plus ion exchange (pitcher) | NSF/ANSI 42 certification from WQA covering chlorine, taste and odor, and zinc |
| Aquasana Claryum Direct Connect AQ-MF-1 | Carbon block feeding your existing faucet | IAPMO R&T certified to NSF/ANSI 42 for chlorine and chloramine, and to NSF/ANSI 53 for lead |
Lead
| Model | Technology | Evidence |
|---|---|---|
| Brita Elite filter OB06 | Pitcher carbon cartridge | Lead under NSF/ANSI 53: NSF lists it with the Pacifica (OB41) and Tidal (OB63) pitchers; IAPMO R&T and WQA list it with their own sets of Brita pitchers |
| PUR PLUS faucet filter RF-9999 | Faucet-mount carbon | Lead under NSF/ANSI 53, listed by NSF and IAPMO R&T |
PFAS
| Model | Technology | Evidence |
|---|---|---|
| PUR PLUS faucet filter RF-9999 | Faucet-mount carbon | Total PFAS under NSF/ANSI 53 (IAPMO R&T) |
| Kinetico K5 Drinking Water Station | Reverse osmosis | PFOA and PFOS under NSF/ANSI 58 (WQA) |
Dissolved solids, nitrate, fluoride, and arsenic
| Model | Technology | Evidence |
|---|---|---|
| Pentair FreshPoint GRO-575B | Tanked reverse osmosis | NSF certified to NSF/ANSI 58 for arsenic (pentavalent), fluoride, lead, TDS, and more |
| Aquasana SmartFlow AQ-SFRO2 | Tanked RO with remineralizer | WQA certified to NSF/ANSI 58 for nitrate, nitrite, fluoride, arsenic (V), TDS, and more |
| Culligan Aquasential Smart RO Nitrate | Tanked RO | WQA listing under NSF/ANSI 58 includes nitrate and nitrite |
Two reading notes for the matrix. A listing covers the contaminants it names, so a filter certified for lead hasn't necessarily been evaluated for nitrate. And nitrate claims can come with conditions: Aquasana's data sheet certifies its nitrate/nitrite reduction "only for water supplies with a pressure of 40 psi or greater," and Culligan limits nitrate claims to its Nitrate models.
Microorganisms Need Their Own Plan
Germs are the one group where filter type alone doesn't settle the question. The CDC notes that most home water filters, such as pitcher or fridge filters, "are not designed to remove germs from your water," and that "Reverse osmosis filters remove germs and some types of chemicals." For a known microbial problem, choose treatment validated for the specific organisms and your source water. These systems state their microbiological claims with conditions:
- NSF Protocol P231 (microbiological purifiers): Culligan's Aquasential RO is listed for bacteria, viruses, and cysts when used with its Advanced Post Tank Filter. Kinetico's K5 meets the purifier requirements when equipped with its Virus/Bacteria Guard (part 12873B), the 3-gallon standard tank, and prefilter 9309A or 9461A.
- NSF/ANSI 55 Class A (UV): UV systems certified to Class A are intended to disinfect contaminated water when used within their specified source-water and operating conditions.
For a private well with a positive bacterial test, treatment needs to address the organisms detected alongside the drinking-water filter, and the drinking-water system needs a rating for the water source you have.
The CDC calls for regular maintenance, cartridge replacement on the manufacturer's schedule included, to keep a filter working properly.
How Viomi's Systems Map to These Contaminant Groups
The two Viomi models featured here use different technologies to address different contaminant groups.

For chlorine taste and odor at a separate drinking faucet. The Viomi Under-Sink Carbon Filter pairs a 2-in-1 cartridge of PP cotton and a carbon rod (0.5-micron precision) with its own drinking faucet, so the main faucet stays as it is. Viomi lists chlorine and unpleasant tastes and odors among the cartridge's reduction targets, which makes it a straightforward fit for the taste-and-odor group. It runs without electricity, connects to the cold supply, and its cartridge lasts up to 12 months on municipal water with a twist-and-lock change.
For lead, PFOS/PFOA, and dissolved solids. The Viomi M1 combines 9-stage tankless RO, a 1000 gallons-per-day rating, and a 3:1 pure-to-drain ratio (for every cup sent down the drain, three come out purified), then adds minerals back for taste in a remineralization stage. In independent SGS testing listed on the product page, the Viomi M1 reduced lead by more than 99.87%, PFOS by more than 99.67%, and PFOA by more than 99.42%, with chlorine and microplastics also covered, and Viomi's certificate page records the PFOS/PFOA reduction testing by SGS with reference to NSF/ANSI 58. Its touchscreen smart faucet displays tap-water and purified-water TDS as a running measure of total dissolved solids, while lead and PFOS/PFOA reduction rests on that contaminant-specific SGS testing. The purified-water TDS reading also reflects the minerals added during remineralization. Cartridge changes are infrequent: the PCB filter runs up to 2 years between swaps, the RO filter up to 4. Set up on municipal tap water, the Viomi M1 needs a standard electrical outlet, a 1/4" drain-pipe hole, and a 1"–1.5" opening for the smart faucet.

When One Filter Isn't Enough
Some water lists call for two steps that each do their own job:
- Hard water plus drinking-water contaminants: scale treatment addresses scale buildup, while an RO system at the kitchen targets the drinking-water contaminants identified in the water report.
- Well water with bacteria plus a chemical concern: a certified disinfection step, plus a filter listed for the chemical.
- Chloramine taste plus lead: one carbon filter can carry both claims. The Aquasana Claryum Direct Connect AQ-MF-1, for example, has IAPMO R&T listings for chloramine under NSF/ANSI 42 and lead under NSF/ANSI 53.
FAQ
Can one filter cover everything on my water report? Sometimes, if the system's evidence names each contaminant you want to reduce and your water fits its operating conditions. The Pentair GRO-575B and Aquasana SmartFlow listings, for example, each cover more than a dozen contaminants. The tables above pair each contaminant with model-level examples, and germs call for a method validated for them.
What should I do about microbes in well water? Start with a lab test for bacteria. If it comes back positive, choose a disinfection method certified for microbiological reduction, such as a UV system certified to NSF/ANSI 55 Class A, used within its specified water conditions, or a system listed under NSF Protocol P231 in the configuration its listing specifies. Use your drinking-water filter for the chemical items on the report.
How do I read a lab report's results? Watch the units first: 1 mg/L equals 1,000 µg/L, and for typical drinking-water results 1 µg/L is about 1 part per billion (ppb), so a lead result of 0.005 mg/L is 5 µg/L, or about 5 ppb. "ND" means not detected under the lab's stated reporting convention (the report's legend gives the detection or reporting limit that applies), and a "<" sign means the result was below the number shown. Compare each result with the limit printed beside it.
Does it matter if hot water runs through the filter? Yes. Most drinking-water filters are rated for cold water, and the EPA's lead guidance says plainly: "Do not run hot water through the filter." Viomi's under-sink carbon filters connect to the cold supply only.
Your Next Moves After the Water Test
- Get the numbers. Download your utility's Consumer Confidence Report, or book a certified lab test if you're on a private well. If your home has older plumbing, brass fixtures, or lead solder, add a lead test of water from your own tap.
- Circle what you want to reduce. Mark each contaminant you want lower, plus any taste or smell that bothers you, and note the result and the limit printed beside it.
- Assign a technology to each item. Use the technology table to sort your list into carbon, RO, and disinfection, and note any item that needs a second step.
- Build a shortlist from the tables. Use the model-level tables in this article to pair each contaminant on your list with a model whose evidence names it, and plan a second step for anything one model doesn't cover.
- Put the replacement date on your calendar. The CDC ties a filter's performance to regular maintenance, so schedule each cartridge change on the day you install it.

Share:
Lead-Removal Filters for New York Homes: Model-Level Evidence, Plumbing and Testing
800 GPD Tankless RO for Indoor Edible Plants: Batches, Flushing and Storage